High Repeatability | High Position Accuracy |
JTH is Suitable for mounting in microscope system and other scanning system.
The XY configuration with an excellent orthogonality.
• High Repeatability
• High Position Accuracy
• Low Thickness
• Travel Range 30mmX30mm To 350mmX350mm
• 5 Phase Stepping motor
• Central Through Hole Structure
Specifications |
Item Number
|
5-JTH90-30-C7 | 5-JTH200-100-C7 | 5-JTH250-130-C7 | 5-JTH360-250-200-C7 | 5-JTH640-350-C7 | |
Clear Aperture
|
37X37mm | 145x122mm | 176x176mm | 190x290mm | 250x250mm | |
Platform Size
|
75X90mm | 200X200mm | 250X250mm | 360X360mm | 400X340mm | |
Travel Range
|
X=30mm,Y=30mm | X=100mm,Y=100mm | X=130mm,Y=130mm | X=250mm,Y=200mm | X=350mm,Y=350mm | |
Resolution 1600 Rev
|
0.625um | 0.625um | 0.625um | 1.25um | 2.5um | |
Screw Positioning Accuracy
|
±50um/300mm | ±50um/300mm | ±50um/300mm | ±50um/300mm | ±50um/300mm | |
Parallelism | 20um | 20um | 20um | 30um | 50um | |
Repeatability | ≤2um | ≤2um | ≤2um | ≤3um | ≤3um | |
Weight | 1.5kg | 4.3Kg | 5Kg | 10Kg | 19Kg | |
2D-Drawing
|
Products | Part Number/Description | Delivery | Price | Qty. | Add to Cart |